Advanced Optimization Strategies for Magnetic Bead DNA Extraction from Trace Biological Evidence

Advanced Optimization Strategies for Magnetic Bead DNA Extraction from Trace Biological Evidence

Optimization Workflow for Magnetic Bead DNA Extraction from Trace Evidence

Step 1
Sample Collection & Pre-Lysis
Step 2
Optimized Lysis
Step 3
Magnetic Bead Binding
Step 4
Stringent Washing
Step 5
Optimized Elution
Step 6
QC & Downstream Assay

Extracting high-quality DNA from trace samples like hair follicles presents a significant challenge for forensic scientists, genealogists, and researchers. The limited biological material, coupled with potent inhibitors and environmental degradation, demands a highly efficient and reliable purification strategy. This comprehensive guide details the critical optimization strategies for magnetic bead-based DNA extraction, specifically tailored for challenging trace evidence. We will explore the fundamental principles that make magnetic beads uniquely suited for this task, examine their performance metrics through relevant data, and provide a practical, step-by-step protocol framework. By understanding and implementing these targeted adjustments, laboratories can significantly improve success rates in downstream applications such as STR analysis and next-generation sequencing from the most minute samples.

Understanding the Unique Challenges of Trace Hair Follicle Samples

Trace Hair Follicle DNA Extraction: Key Challenges & Pre-Lysis Protocol

Core Challenges of Trace Hair Follicle Samples
Low nucleated cells (hundreds vs millions in blood)
Keratin/melanin PCR inhibitors
Environmental contaminants (soil/humic acids)
DNA degradation/fragmentation
Microscopic Selection
Select roots with visible follicular tissue
Layered Washing
Detergent → Purified water → Ethanol rinse
Enhanced Lysis
Increased Proteinase K + DTT + Extended incubation

Hair follicles, particularly those recovered from forensic scenes or historical specimens, represent a prime example of a low-copy-number DNA source. The primary challenge lies in the exceedingly small number of nucleated cells present at the follicular root. Unlike a blood stain, which contains millions of leukocytes, a plucked hair may yield only a few hundred viable cells, placing the entire extraction process at the limit of detection for many protocols. Success hinges on maximizing the recovery of every available DNA molecule while simultaneously eliminating a complex mixture of co-purifying substances that can inhibit enzymatic reactions.

These inhibitory substances are numerous. Keratin, the structural protein of hair, can interfere with binding chemistry. Melanin, a common pigment, is a well-known polymerase inhibitor in downstream PCR. Furthermore, trace evidence is rarely pristine; samples are often exposed to environmental contaminants like soil, dust, or microbial flora, which introduce additional polysaccharides, humic acids, and microbial DNA. Standard, one-size-fits-all extraction protocols often fail under these conditions, leading to low yields or complete PCR inhibition. Therefore, a specialized approach beginning with meticulous sample collection and pre-treatment is non-negotiable for reliable results from hair follicles and similar materials.

The Critical Importance of Sample Collection and Pre-Lysis Treatment

Optimal extraction begins long before the sample reaches the magnetic beads. For hair, visual examination under a microscope to select roots with visible follicular tissue is a crucial first step. Cutting the shaft too far from the root will result in failure, as the hair shaft itself contains primarily degraded mitochondrial DNA. Once selected, a physical pre-wash is often necessary to remove external contaminants. A brief rinse in a dilute detergent or saline solution, followed by rinses in purified water and ethanol, can remove surface debris without lysing the precious internal cells. For heavily soiled samples, such as those encountered in environmental sampling contexts, this step is vital.

Following cleaning, an adapted lysis strategy is required. Standard proteinase K digestion buffers may need enhancement. Increasing the concentration of proteinase K, extending the digestion time to several hours or even overnight, and incorporating a reducing agent like DTT to break down keratin disulfide bonds can dramatically improve cell wall and nuclear membrane disruption. For ancient or highly degraded samples, a gentle lysis condition that minimizes further DNA shearing is prioritized over aggressive, high-temperature protocols. This careful pre-lysis phase ensures maximal release of intracellular DNA into a solution primed for efficient binding in the next step.

Addressing the Problem of Co-Purifying Inhibitors

The lysate from a hair follicle is a complex soup containing the target DNA amid a vast excess of problematic compounds. Melanin and keratin fragments pose a significant threat to downstream analysis. Modern magnetic bead kits designed for forensic or difficult samples often include specialized inhibitor-removal technology within their binding or wash buffers. These additives work by competitively binding to the inhibitor molecules or altering their solubility, preventing them from co-precipitating with the DNA on the bead surface.

For particularly challenging cases, additional pre- or post-extraction purification steps may be integrated. Some protocols recommend a brief silica-column clean-up of the final eluate from a magnetic bead extraction as a secondary polish. The choice of wash buffers is also paramount. Ensuring thorough washing with the recommended ethanol-based buffers is essential, and for samples suspected of high inhibitor loads, an additional wash step with a specialized wash buffer or a slightly elevated ethanol concentration can be incorporated to more stringently remove salts and organic contaminants without desorbing the DNA from the beads.

The Core Mechanism: Why Magnetic Beads Excel with Trace Evidence

Magnetic Beads vs. Column-Based Extraction: Core Advantages for Trace DNA

Performance CriterionMagnetic Bead ExtractionColumn-Based ExtractionKey Benefit for Trace Samples
Binding KineticsSolution-phase (homogeneous bead suspension)Membrane-surface (random flow contact)Maximizes contact with rare DNA molecules
Sample HandlingClosed-tube (no transfers)Multiple tube/membrane transfersMinimizes DNA loss & cross-contamination
Elution VolumeLow (10-20 µL) for concentrationHigh (50-100 µL) (membrane retention)Concentrates trace DNA for direct PCR
Contamination RiskLow (no aerosol from centrifugation)High (centrifugation/airflow aerosol)Critical for forensic/clinical low-copy DNA
Automation CompatibilityFully compatible (programmable liquid handling)Poor (manual centrifugation/filtration)Ensures reproducibility for high-throughput

Magnetic bead technology is fundamentally superior for trace DNA recovery due to its solution-phase binding kinetics and minimal sample handling. The process revolves around superparamagnetic beads, typically composed of an iron oxide core coated with a silica or functionalized polymer surface. In a high-concentration chaotropic salt environment created by the binding buffer, water molecules are strongly organized around the salt ions. This forces hydrophobic molecules, like the silica surface and the DNA backbone, to interact. DNA adsorbs onto the bead surface through hydrogen bonding and van der Waals forces, while proteins and other contaminants remain in solution.

The key advantage for low-volume samples is the efficiency of this interaction. Unlike column-based methods where DNA must flow through and randomly contact a membrane, magnetic beads are homogenously suspended throughout the entire lysate volume. This maximizes the chance of contact between every single DNA molecule and a binding site, a critical factor when the total number of molecules is low. Once binding is complete, a simple external magnet is applied to the tube. The beads, now adorned with DNA, migrate to the side of the vessel, allowing the contaminated supernatant to be pipetted away cleanly without centrifugation or membrane transfers that can lead to bead or sample loss.

Optimizing Binding Conditions for Maximum DNA Capture

For trace samples, default binding conditions may not be sufficient. The primary variable is the ratio of sample lysate volume to binding buffer and beads. It is often advisable to maintain the total binding volume as small as feasibly possible to keep the DNA concentration high, thereby driving the binding equilibrium toward the bead surface. If the original lysis volume is large, a concentration step prior to adding beads, or simply adding a proportional amount of beads, should be considered.

The binding time itself can be extended. While many rapid protocols recommend 5-10 minutes, allowing the bead-DNA mixture to incubate for 15-20 minutes at room temperature with gentle agitation can increase the yield from samples with very low starting material. The composition of the binding buffer is also crucial; ensuring it contains an optimal concentration of chaotropic salts like guanidine hydrochloride is vital for creating the correct chemical environment for silica-DNA interaction. For samples like hair, which share challenges with other inhibitor-rich sources, using a kit specifically formulated for forensic hair samples or keratinous materials is recommended, as their buffers are optimized for these matrices.

Mastering the Wash and Elution Phases for Purity and Yield

The wash steps are where purity is won or lost. The goal is to remove all salts, alcohols, and residual inhibitors without accidentally dislodging the target DNA. For trace samples, the risk of losing DNA during washing is heightened. Therefore, wash buffers must be applied thoroughly but carefully. It is essential to completely resuspend the bead pellet during each wash to ensure all bead surfaces are exposed to the cleaning solution. Leaving beads clumped can trap contaminants in the center of the clump.

Equally important is the complete removal of wash buffer. Any residual ethanol carried over into the elution step will severely inhibit downstream enzymatic reactions. After the final wash, a brief drying step of the bead pellet by leaving the tube open at room temperature for 5-10 minutes allows residual ethanol to evaporate. However, over-drying can make DNA difficult to elute. The elution itself benefits from optimization. Using a pre-warmed elution buffer (e.g., 55-70°C) and allowing it to incubate on the resuspended beads for 3-5 minutes before magnetic separation can significantly improve the efficiency of DNA desorption from the silica surface into the final aqueous solution.

Validating Performance: Metrics for Successful Trace DNA Extraction

Key Performance Metrics & Industry Standards for Trace DNA Extraction

Validation MetricIndustry Acceptable StandardInterpretation
DNA Recovery Efficiency>70%High recovery of low-input DNA molecules
A260/A280 Absorbance Ratio1.7 - 1.9Minimal protein (keratin/melanin) contamination
A260/A230 Absorbance Ratio>2.0No carryover of chaotropic salts/PCR inhibitors
Downstream PCR PerformanceRobust, balanced amplificationFunctional DNA suitable for STR/NGS/SNP analysis
ReproducibilityInter/intra-assay CV <10%Consistent results for evidentiary/diagnostic use
Mandatory Quality Control Controls for Each Extraction Batch
Negative Control (Extraction Blank)
Monitors reagent/equipment contamination
Low-Input Positive Control
Validates extraction efficiency for trace DNA
Degradation Monitor (if applicable)
Assesses DNA integrity for aged/environmental samples

The success of an optimized magnetic bead protocol for hair follicles is measured by both quantitative and qualitative outputs. Yield, typically measured by fluorometry, is important but can be misleading for trace samples. A yield of just a few nanograms may represent a 90% recovery from a single hair follicle, which is an excellent result. The more critical metrics are purity, as indicated by absorbance ratios (A260/A280 and A260/A230), and, most importantly, functional performance in downstream assays. A high A260/A230 ratio is particularly crucial, as low values indicate carryover of chaotropic salts or other organic compounds that are potent PCR inhibitors.

Industry standards and validation studies provide benchmarks. A well-optimized magnetic bead protocol for trace evidence should consistently achieve DNA recoveries above 70% from defined low-input samples, with A260/A280 ratios between 1.7 and 1.9 and A260/A230 ratios above 2.0. The true test, however, is amplification. The extracted DNA must support robust and reliable PCR amplification, whether for short tandem repeat (STR) profiling, mitochondrial DNA sequencing, or single nucleotide polymorphism (SNP) analysis. The generation of full, balanced STR profiles from a single hair follicle is the definitive performance indicator for forensic applications.

Assessing DNA Integrity and Suitability for Advanced Applications

Beyond concentration and purity, the integrity of the extracted DNA is paramount, especially for applications like next-generation sequencing (NGS). DNA from aged or environmentally stressed hair follicles is often fragmented. While magnetic bead methods do not inherently shear DNA like vigorous pipetting or vortexing can, they also do not selectively isolate long fragments. The size distribution of the eluted DNA will reflect the input material. Gel electrophoresis or fragment analyzers can be used to assess the average fragment size.

For massively parallel sequencing, the presence of high-molecular-weight DNA is less critical than for cloning, but the library preparation success depends on having sufficient quantities of amplifiable fragments. An optimized trace extraction protocol should yield DNA that is compatible with modern, low-input NGS library prep kits. This demonstrates that the extract is not only pure but also free of enzymatic inhibitors that could block end-repair, adapter ligation, or PCR amplification during library construction, similar to requirements for DNA from degraded FFPE samples.

Reproducibility and Cross-Contamination Controls

In forensic and clinical settings, reproducibility and preventing contamination are as important as yield. Magnetic bead systems excel here due to the closed-tube nature of the process after initial lysis. The beads are moved and washed within the same tube, minimizing opportunities for aerosol contamination. Furthermore, the implementation of these protocols on automated liquid handling workstations standardizes every pipetting step, eliminating human variability and significantly improving inter- and intra-assay reproducibility.

Laboratories must incorporate rigorous negative controls (extraction blanks) to monitor for reagent contamination and positive controls with known, low-quantity DNA to validate each batch of extractions. The use of magnetic bead-based kits designed for forensic samples often includes quality control measures and are manufactured under conditions that minimize human DNA contamination, adhering to standards like ISO 18385. This level of control is essential when results have evidentiary or diagnostic significance.

Broadening the Scope: Application to Other Demanding Sample Types

Magnetic Bead Protocol Adaptations for Diverse Trace Sample Types

Touch DNA (Skin Cells)
Key Challenge: Ultra-low cell count (1-10 cells)
       Adaptations:
       • Optimized collection (swab/tape lifting)
       • Minimal lysis volume
       • 10 µL elution for maximum concentration
       Core Application: Forensic object contact evidence
Botanical/Environmental DNA
Key Challenge: Polysaccharides/polyphenols inhibitors
       Adaptations:
       • PVP-added lysis buffer (binds polyphenols)
       • Pre-wash for sugar removal
       • Large-surface-area beads for dilute eDNA
       Core Application: Pollen/seeds, water/soil eDNA
Circulating Tumor DNA (ctDNA)
Key Challenge: Short fragments + low wild-type ratio
       Adaptations:
       • Size-selective bead binding
       • Cell-free DNA optimized buffers
       • No mechanical disruption
       Core Application: Clinical liquid biopsy/diagnostics
Archival FFPE Tissues
Key Challenge: Formalin cross-links + degradation
       Adaptations:
       • Deparaffinization pre-step
       • Extended proteinase K digestion
       • Inhibitor-removal wash buffers
       Core Application: Clinical/historical tissue archives
Universal Optimization Principles for All Trace Samples
Maximize Lysis Efficiency → Concentrate Binding Volume → Stringent Inhibitor Removal → Low-Volume Elution

The optimization strategies developed for hair follicles are directly transferable to a wide array of other challenging trace and inhibitor-rich samples. The underlying principles—maximizing cell lysis, optimizing binding for low-copy-number DNA, and implementing stringent washes for purity—are universally applicable. For instance, buccal swabs collected from newborns or historical archives often have very few epithelial cells. Applying an extended proteinase K digestion and a concentrated binding approach with magnetic beads can greatly improve yields compared to standard protocols.

Touch DNA samples, consisting of a few skin cells left on handled objects, represent the ultimate challenge in trace evidence. Here, every aspect of the protocol is pushed to its limit. The initial collection method (e.g., swabbing versus tape lifting) and the choice of lysis buffer are critical. Magnetic bead extraction is the preferred method for these samples due to its high recovery efficiency and low elution volume, which concentrates the final DNA into a few microliters suitable for direct addition to a PCR reaction. The techniques mirror those used for other skin cell samples.

Adapting the Protocol for Plant and Environmental Trace Evidence

Botanical trace evidence, such as a single seed fragment or a few pollen grains, presents a different set of inhibitors, primarily polysaccharides and polyphenols. The magnetic bead protocol requires adaptation at the lysis stage. A pre-lysis wash with a compatible buffer to remove simple sugars might be introduced. More commonly, the lysis buffer itself is modified to include compounds like polyvinylpyrrolidone (PVP) which binds polyphenols, preventing them from oxidizing and degrading DNA. The binding and wash steps then proceed similarly, with the magnetic beads effectively removing the remaining contaminants.

Environmental DNA (eDNA) from water or soil filters, where the target organism's DNA is extremely dilute amidst vast amounts of environmental and microbial DNA, is another ideal application. The scalable nature of magnetic beads allows for processing large volumes of lysate to capture the rare target molecules. The protocol involves filtering large amounts of water, lysing the captured material, and then using a large-surface-area magnetic bead system to harvest the DNA. This approach is fundamental to modern aquatic eDNA studies and biodiversity monitoring.

Use in Clinical and Archival Contexts

In clinical diagnostics, circulating tumor DNA (ctDNA) in blood plasma is a classic trace DNA target. These fragments are short and exist at very low concentrations relative to the background of wild-type DNA. Magnetic bead kits optimized for cell-free DNA employ size-selective binding or clean-up strategies to enrich these fragments. Similarly, extracting DNA from a limited number of sorted cells or a fine-needle aspirate biopsy for molecular testing requires the same sensitivity and purity as forensic trace evidence.

Archival samples, such as FFPE tissues where the material is scarce, also benefit. While the initial deparaffinization and lysis steps differ, the subsequent purification on magnetic beads is highly effective at removing melanin (from skin biopsies), formalin-induced cross-links, and other decay products, yielding DNA suitable for PCR and targeted sequencing assays even from very small tissue curls or microdissected areas.

A Practical Framework for Protocol Optimization

Practical Step-by-Step Protocol Optimization Framework

1
Select a Forensic/Low-Input Optimized Commercial Kit
Choose kits formulated for trace/inhibitor-rich samples (pre-optimized buffers for keratin/melanin/PCR inhibitors)
2
Establish Baseline with Control Samples
Test manufacturer’s standard protocol with simulated trace samples (quantified diluted DNA/low-cell-count controls) to measure baseline yield/purity/PCR performance
3
Optimize One Variable at a Time (Systematic Iteration)
Order: Lysis conditions (time/enzyme/DTT) → Binding (time/volume/bead amount) → Wash/Elution (washes/dry time/temperature/volume) | Evaluate all changes by yield, purity ratios and downstream assay success
4
Automate & Standardize (For Throughput/Reproducibility)
Translate optimized manual protocol to automated liquid handling platforms → Program precise incubation/mixing/handling parameters to eliminate human variability
5
Document as SOP & Implement QA/QC
Formalize optimized protocol as a validated SOP (track reagents/equipment/acceptance criteria) → Implement batch QC controls and longitudinal data tracking for audits/accreditation

Developing a robust in-house protocol for trace DNA extraction using magnetic beads is a systematic process. It begins with selecting an appropriate commercial kit that is advertised for low-yield or forensic samples, as these will have the most suitable buffer formulations. The next step is to establish a baseline using the manufacturer's standard protocol with a control sample that simulates your target material, such as a quantified, diluted DNA sample or a known low-cell-count sample.

From this baseline, one variable should be altered at a time to assess its impact. A logical progression is to first optimize the lysis conditions (time, temperature, enzyme concentration), then the binding conditions (time, volume, bead amount), and finally the wash and elution steps (number of washes, dry time, elution buffer volume and temperature). Each iteration must be evaluated not just by DNA yield, but by the purity ratios and, definitively, by the success rate and peak heights in the final downstream assay, be it qPCR, STR, or sequencing.

Implementing Automation for Consistency and Scale

For laboratories processing more than a few samples per week, manual optimization reaches its limit in terms of reproducibility and throughput. Translating the optimized manual protocol to an automated magnetic bead extraction platform is a powerful next step. Platforms from leading manufacturers allow the programming of precise incubation times, mixing speeds, and liquid handling sequences. This eliminates manual pipetting errors and ensures every sample is treated identically.

Automation also enables the simultaneous processing of different sample types on the same run by calling different pre-programmed protocols. A workstation could be tasked with extracting DNA from hair follicles, buccal swabs, and touch DNA swabs in a single batch, applying the specific optimizations for each. This dramatically increases laboratory capacity and standardizes the pre-analytical phase, which is a major source of variability in genetic testing. Exploring the range of available magnetic bead kits compatible with your automation system is a key step in this scaling process.

Documentation and Quality Assurance

Any optimization effort must be thoroughly documented. A final optimized protocol should be written as a standard operating procedure (SOP), detailing every step, reagent lot number tracking, equipment settings, and acceptance criteria for controls. This SOP should be validated under the laboratory's specific conditions, demonstrating its reliability over multiple runs and different operators.

Quality assurance involves running the specified controls with every batch. This includes a negative control to monitor contamination, a positive control with a challenging but known sample to ensure the process is working, and perhaps a degradation monitor if analyzing aged samples. The data from these controls, along with the yield and purity metrics from casework or research samples, should be tracked over time. This longitudinal data is invaluable for troubleshooting, for demonstrating the method's robustness during audits or accreditation, and for identifying when a reagent lot change or other variable necessitates a re-optimization.

Troubleshooting Common Issues in Trace DNA Extraction

Troubleshooting Common Issues in Trace Magnetic Bead DNA Extraction

<td style="padding:10px; border:1px solid #ddd; DNA fragments too short for standard amplicons
Common IssueRoot CauseDiagnostic CueSolution & Remediation
DNA detected by fluorometry, but PCR failureResidual inhibitors (salts/keratin/melanin) not removedLow A260/A230 ratio (<2.0)• Add extra specialized inhibitor-removal wash
• Ensure full bead resuspension during washes
• Post-extraction silica bead clean-up (small volume)
• Increase ethanol concentration in wash buffer
No measurable DNA yieldInsufficient lysis or poor bead binding
• Faulty reagents (proteinase K/binding buffer)
• Inadequate lysis time/enzyme concentration
Positive control fails (reagent issue)
Only trace samples fail (lysis issue)
• Replace expired proteinase K/binding buffer
• Increase proteinase K concentration + add DTT
• Extend lysis time (overnight) or add mild mechanical disruption
• Verify correct bead type/amount for low-volume binding
Bead carryover in eluate (PCR inhibition)Improper magnetic separation or pipetting
• Incomplete bead pelleting
• Pipette tip touching bead pellet
Visible beads in eluate; PCR no amplification• Extend magnetic separation time (2-3 mins)
• Pipette eluate from opposite side of bead pellet
• Use low-retention pipette tips
• Brief low-speed centrifugation before magnetic separation
Low elution efficiency (low yield)Over-drying of bead pellet or cold elution buffer
• Inadequate DNA desorption from silica surface
Low fluorometry yield; normal purity ratios• Minimize dry time (5-10 mins only, no heat)
• Use pre-warmed elution buffer (55-70°C)
• Incubate elution buffer with beads for 3-5 mins before separation
• Resuspend bead pellet fully in elution buffer
STR/NGS failure (degraded samples)Low molecular weight DNA on gel/fragment analyzer; partial/no STR profile• Optimize extraction for short fragments (no harsh steps)
• Switch to mini-STR kits/SNP panels (short amplicons)
• Use NGS protocols designed for degraded DNA
• Avoid excessive pipetting/vortexing (minimize shearing)

Despite careful optimization, challenges can arise. A common result is the successful extraction of DNA as measured by fluorometry, but a subsequent failure in PCR amplification. This almost always indicates the presence of inhibitors that were not removed during the wash steps. Investigating this requires analyzing the purity ratios; a low A260/A230 ratio is a clear indicator. The remedy is often to revisit the wash strategy, potentially adding an extra wash with a specialized buffer or ensuring the bead pellet is fully resuspended during washing. For persistent inhibitors, a post-extraction clean-up using a dedicated silica bead clean-up kit in a small volume can be effective.

Conversely, a failure to obtain any measurable DNA suggests a problem with cell lysis or binding. If the positive control fails, the batch of proteinase K or binding buffer may be faulty. If only the trace samples fail, the lysis conditions are likely insufficient. Increasing the proteinase K concentration, adding a mechanical disruption step (like bead beating in a microtube), or extending the digestion time should be considered. It is also critical to verify that the correct type and amount of magnetic beads are being used, as some kits have beads with different binding capacities.

Addressing Low Elution Volume and Bead Carryover

When working with trace DNA, the final elution volume is kept small (e.g., 10-20 µL) to concentrate the sample. This can make pipetting the final eluate difficult, especially if a small number of magnetic beads are accidentally aspirated. Bead carryover can inhibit PCR. To minimize this, after the final elution and magnetic separation, carefully pipette the eluate from the side of the tube opposite the bead pellet, and avoid touching the tip to the tube wall where beads may adhere. Using low-retention pipette tips is highly recommended.

If bead carryover is a consistent issue, a brief, low-speed centrifugation step after the final elution and before placing the tube on the magnet can help pull any suspended beads to the bottom. The tube is then placed on the magnet, and the cleared eluate is removed. This extra step must be balanced against the risk of sample loss or contamination from the additional handling.

Managing Expectations with Severely Degraded Samples

Not every sample will yield a full genetic profile. Extremely old, burned, or environmentally ravaged biological material may contain DNA that is too degraded for standard STR analysis, which requires fragments of several hundred base pairs. In these cases, success may be found by targeting shorter amplicons. This shifts the focus of the extraction from maximizing yield of long DNA to maximizing the yield of very short fragments and ensuring they are inhibitor-free.

Protocols can be adjusted to avoid any steps that might preferentially lose short fragments. The magnetic bead binding conditions for short fragments are generally efficient. The downstream assay must then be adapted, moving to mini-STR kits, SNP panels with very short amplicons, or whole genome sequencing techniques designed for degraded DNA. Understanding that the extraction protocol is one link in a chain, and aligning it with an appropriate analysis method, is the key to unlocking information from the most demanding trace evidence, much like approaches used for ancient bone samples.

Contact Us